Article: Decking Joist Spacing: 400 mm Centres, Joist Count Table & Subframe Sizes
Decking Joist Spacing: 400 mm Centres, Joist Count Table & Subframe Sizes
Joist spacing for THQ composite decking is 400 mm centres when the boards run square (90 degrees) to the joists, and 300 mm centres when the boards run diagonally at 45 degrees. "Centres" means the distance from the middle of one joist to the middle of the next. Get this number right before you order timber, because it sets how many joists, clips and screws the job needs.
This guide covers the spacing, how to count joists for any deck size, which treated pine sizes are used for the subframe, and a worked example you can copy for your own quote.
Decking joist spacing at a glance
| Board layout | Joist spacing (centre to centre) |
|---|---|
| THQ composite boards laid square to the joists | 400 mm |
| THQ composite boards laid diagonally (45 degrees) | 300 mm |
| Commercial decks and stairs | 400 mm |
Diagonal boards need closer joists because each board crosses the gap on an angle, so the unsupported length is longer than the joist spacing itself. The 400 mm spacing applies to residential decks, commercial decks and stairs alike. These figures are for THQ's co-extrusion composite decking boards, both the Signature and Builder ranges. If you are using another brand, use that manufacturer's figure.
Why composite decking needs closer joists than many old timber decks
Composite boards are more flexible than hardwood of the same thickness, and they soften slightly in summer heat. Joists that are too far apart let the boards flex and dip between supports. Many older timber decks were framed at around 450 mm centres. If you are re-decking an existing frame with composite, measure the joists first. Where the spacing is wider than 400 mm, add extra joists between the existing ones before the boards go down.
How many joists do I need?
Measure the side of the deck that the joists are spaced along (the direction the boards run), divide by the spacing, round up, and add one for the end joist.
Joists = (deck length in mm ÷ spacing in mm, rounded up) + 1
| Deck length along the boards | Joists at 400 mm centres | Joists at 300 mm centres (diagonal boards) |
|---|---|---|
| 2.4 m | 7 | 9 |
| 3.0 m | 9 | 11 |
| 3.6 m | 10 | 13 |
| 4.2 m | 12 | 15 |
| 4.8 m | 13 | 17 |
| 5.4 m | 15 | 19 |
| 6.0 m | 16 | 21 |
Allow extra joists or blocking wherever two board ends meet, so each board end sits on its own solid support, and around the perimeter where fascia boards are fixed.
What timber to use for the deck subframe
H3 treated pine is the most common subframe timber under composite decking in Australia. H3 is the hazard level for timber used outdoors above the ground, which covers joists and bearers. Any timber set in the ground, such as posts in soil or concrete, needs H4 or higher. See H3 vs H4 treated pine for the full breakdown.
THQ's H3 treated pine framing is MGP10 / F7 structural pine, LOSP treated, in these sizes:
| Size | Lengths | Typical subframe use |
|---|---|---|
| 70 x 45 mm | 3.6 m | Light framing and blocking |
| 90 x 45 mm | 3.6 m and 5.4 m | Joists on low decks with close supports |
| 140 x 45 mm | 3.6 m and 5.4 m | Joists and bearers that need to span further |
Joist spacing and joist span are two different things. Spacing is the gap between joists (400 mm or 300 mm, set by the decking board). Span is how far each joist or bearer runs between its supports, and it depends on the timber size, the stress grade and the load. Take spans from AS 1684 or from your builder or engineer. A deck that is raised, attached to the house or carrying a spa should be checked by a professional and may need a building permit.
Subframe checks before the boards go down
- Joists run at 90 degrees to the boards. Decide the board direction first, then lay out the frame.
- Level and flat. Any twist or step in the frame shows through the finished deck surface.
- Airflow underneath. Leave at least 50 mm clearance between the bottom of the joists and the surface below so the frame can dry out.
- Board gaps. THQ 2 mm stainless steel hidden deck clips set the side gap between boards. Leave 5 to 8 mm at board ends and where boards meet a wall.
- Stainless fixings. Use stainless steel screws, especially near the coast.
The full board-laying sequence is in the composite decking installation guide.
Worked example: 5.4 m x 3.6 m composite deck
A deck 5.4 m long and 3.6 m deep, with 5.4 m boards laid square to the joists:
- Joists: 5,400 ÷ 400 = 13.5, rounded up to 14, plus 1 = 15 joists, each 3.6 m long.
- Boards: THQ Signature boards are 140 x 24 mm and 5.4 m long. With a 2 mm gap each row takes up 142 mm, so 3,600 ÷ 142 = 26 rows (26 boards, about 19.7 m² of board for a 19.4 m² deck). Builder range boards are 142 x 22 mm and 5.4 m long, so each row takes up 144 mm and the same deck needs 25 rows.
- Hidden clips: one clip wherever a board crosses a joist. 15 joists x 26 rows = about 390 clips, or 8 packs of 50.
Add 10 to 15 percent to the board quantity for cuts and waste, plus bearers, posts, fascia and screws to suit your design. For a quick board count on any size, use the THQ decking calculator.
Decking joist spacing FAQs
What is the standard joist spacing for composite decking?
For THQ composite decking it is 400 mm centres with boards laid square to the joists, and 300 mm centres for diagonal boards. Other brands publish their own figures, so always check the installation guide for the board you are buying.
Does the 400 mm joist spacing apply to commercial decks and stairs?
Yes. THQ composite decking uses 400 mm joist centres on commercial decks and on stairs, the same as a residential deck.
Can I lay composite decking on joists at 450 mm centres?
Not with THQ boards. 400 mm is the widest spacing for a square layout. On an existing frame at 450 mm, add joists between the existing ones to bring the spacing down before laying the boards.
How far apart should joists be for diagonal decking?
300 mm centres for THQ composite boards laid at 45 degrees.
What size timber should deck joists be?
90 x 45 mm and 140 x 45 mm H3 treated pine are the common joist sizes. The right one depends on how far the joist spans between bearers. Take the span from AS 1684 or your builder.
Is H3 treated pine suitable for a deck subframe?
Yes, for joists and bearers that sit above the ground. Posts or any timber in contact with the ground need H4 or higher.
How many deck clips do I need?
One clip for every point where a board crosses a joist. Multiply the number of joists by the number of board rows, then divide by 50 to get packs.
Order boards and subframe timber together
THQ has supplied decking to builders, landscapers and homeowners for 15+ years at factory-direct prices. Composite boards, H3 treated pine framing, clips and decking accessories go out on the same delivery across Victoria and South East Queensland, or can be picked up from our warehouses. Trade accounts get trade pricing. Order free samples to check colours before you commit, or call 1800 084 700 with your deck size and we will work out the board, joist and clip quantities with you.